Openreach Fault Tracker Jargon Buster
|
Code |
Description |
|
A/C or AEC |
Ariel Cable |
|
A1024 |
notice on pole to advise needs replacing |
|
A108 |
notice left by engineer to advise no access and to call us to appoint |
|
A55 |
Report submitted for permission to do work i.e a dig/traffic lights |
|
AAD |
Actioned After Delay |
|
AAE |
Aborted After Execution - The activity has been aborted |
|
ACT |
Action - The activity can be worked on and no reason has been given why it has not been completed |
|
AC |
Aerial Cable - A main cable that travels overhead between poles usually only found rurally |
|
ADSL |
Asymmetric Digital Subscriber Line - the technology for providing Broadband service - faster in one direction than the other |
|
ALM |
Alarm |
|
AOC |
Access Operations Centre- Supplier network management |
|
APF |
Apparatus Fault |
|
APPT |
Appointment |
|
ARA |
Arrange Appointment |
|
ASG |
Application Support Group |
|
ASQ |
Assigned from another queue |
|
ASSIST |
This is when an engineer has requested assistance with the order |
|
|
|
|
BBCR |
Broadband Customer Reporting |
|
BFT |
Brown Fibre Tubing |
|
BLOCK TERMINAL |
Sometimes called BT. This is a small connection point in the customer's premises and is usually used to connect external wiring to the internal wiring, e.g.: for an alarm |
|
BMWin-Mac |
This indicates a managed install module for Fibre |
|
BNR |
Bell Not Ringing |
|
BR |
Bell Ringing |
|
BTA |
BT Answer |
|
Bar Pair |
The unique identifier for the termination of the E-side on the MDF |
|
Battery Contact |
More electricity going through than there should be |
|
Bridge Case |
A case reference given to track faults and resolve system incidents |
|
|
|
|
CAB |
Cabinet In Street (green box) |
|
CAC |
Completed Awaiting Confirmation |
|
CAN |
Cancelled - The activity has been cancelled |
|
CARO |
Channel Allocation and Routing Office |
|
CA |
Customer Apparatus |
|
CA |
Fault found on Customers Apparatus |
|
CCS |
Call Minder |
|
CDT |
Continuous Dial Tone |
|
CE |
Customer Engineer |
|
CE |
Fault found at Customers End |
|
CF |
Cable Fault |
|
CF |
Exchange Common Fault |
|
CIE |
Called in Error |
|
CLI |
Calling Line Identity (Telephone Number) |
|
CMC |
Customer Management Centre, also known as "SMC" - Service Management Centre |
|
CNJ |
Contact No Joy |
|
COM |
Completed - The activity is complete. |
|
CONO |
Contact Number |
|
CORD |
Cancel Order |
|
COW |
Cable on Wall |
|
CO |
Cuts Off |
|
CPO |
Central Planners Office |
|
CP |
Communications Provider- Open reach is BT Wholesale local access providers, so BTW is a CP to Open reach |
|
CP |
Customer Premises or Customer Product |
|
CP |
Cuts off |
|
CRO |
Central Records Office |
|
CSE |
Customer Service Engineer |
|
CSNO |
Customer Services Network Operations - These are the engineers responsible for end to end provision and fault repair. More recently referred to as CST provision or CST repair |
|
CSP |
Customer Splice Point. This is the equipment on the outside wall of the property |
|
CS |
Local Network - Confined Space Work |
|
CUG |
Closed User group- a customer account code in One Siebel |
|
CWB |
Cavity Wall Box |
|
CWC |
Complete With Changes |
|
CWWC |
Confirmed Working with End user |
|
CWWEU |
Confirmed Working With End user |
|
Cabinet |
Alternative name for the Primary Connection Point |
|
Cable Chamber |
Underground room beneath an exchange where the E-side cables enter the exchange |
|
Cat and Genny |
C.A.T (Cable Avoiding Tool). A Genny signal transmitter works with the "Cable avoiding tool" |
|
Cherry Picker |
Machinery used to reach higher level equipment |
|
Common Fault |
A group faults linked to a primary fault (primary fault will hold all notes and info) |
|
Crimp |
how engineers connect 2 up a line in a PCP or in a junction box |
|
|
|
|
D POLE |
A telegraph pole that is dangerous to climb because it is rotten. Decayed Pole. This can cause a provision order or a fault to be delayed |
|
D and T |
Demonstrated and tested |
|
D-side |
The cable running from the Primary Connection Point to the Distribution Point |
|
DACS |
Digital Audio Carrier System, a PGD technology |
|
DAE |
Delayed After Execution as DBE but the user has tried to complete |
|
DAJ |
Display Activities on the Job |
|
DBE |
Delayed Before Execution - The user finds a reason why the work cannot be completed. This will be accompanied by a delay code and progress notes |
|
DCL |
Display Contact List |
|
DCN |
Drop in connection |
|
DCO |
Display Customer Orders |
|
DCP |
Display Customer Premises |
|
DCRD |
Display Customer Rental Details |
|
DCS |
Display customer Service |
|
DC |
Distance to Fault (Customers Premises) |
|
DEL |
Display Exchange Lines |
|
DE |
Distance to Fault (External DP) |
|
DFJ |
CSS transaction - Display Frames Jumpering |
|
DFRD |
Display Fault Report Details |
|
DFRL |
Display Fault Report List |
|
DFRN |
Display Fault Report Notes |
|
DG |
DIG Queues |
|
DIO |
Display Installation Orders |
|
DIS U/G |
Relates to a fault and means that the line is disconnected underground |
|
DIS |
Disconnection |
|
DISC |
Discount |
|
DI |
Distance to Fault (Internal DP) |
|
DLI |
Direct Lead In |
|
DLTR |
Display Line Test Results |
|
DN |
Directory Number |
|
DOA |
Dead On Arrival (0 to 2 days) |
|
DOL |
Display Order Lines |
|
DO |
Display Order |
|
DPID |
Display Product/ Service by ID |
|
DPN |
Display Product Name |
|
DP |
Distribution Point (DP) - This is the point near to a premise where the main cable from a PCP is split in order to provide service at one or more localised premises. A DP can be at the top of a telegraph pole (Overhead DP), under a walkway (Underground DP) or on the side of a building |
|
DRA |
Report Damage Apparatus |
|
DROP-WIRE (DW) |
A pair of wires that travels overhead to a customer's premises from the telegraph pole |
|
DRO |
Damage Report Overhead / Damage to aerial cables - Overhead, Pole Damage, Dropwires etc |
|
DRT |
CSS transaction Display Routing |
|
DRU |
Damage Report Underground / Damage outside end user premises - Underground Cables, Cabinets, Manholes etc |
|
DRW |
Damage Report Wiring (Internal) |
|
DR |
Distance to Fault (Ring Type DP) |
|
DSLAM |
Digital Subscriber Line Access Multiplexor - exchange equipment used for providing Broadband service |
|
DTA |
Dial Tone in Answer |
|
DT |
Diagnostic Test - test results are inconclusive so line sent for further testing to a Diagnostic Test Officer |
|
DU |
Distance to Fault (U/G DP) |
|
DWI |
Display Works Instructions |
|
DX |
Distance to Fault (DP Type Unknown) |
|
Disconnection |
Broken/damaged wire or cable |
|
Duct |
The pipe holding cables |
|
|
|
E POLE / L POLE
|
This pole has a dual purpose, either it carries electric cables, E, or it is a street lamp, L. Delays can arise in service provision if one of these poles exists because of safety regulations and requirements |
E-Response |
Activity raised by SMC when a job is stuck within the system to get this moving again. |
E-side |
The cable running from the Primary Connection Point to the Exchange |
EAN |
Enter Action Narrative |
EAOS |
Engineer Arrived On Site |
EAP |
Engineer Assigned Provisionally |
ECD |
Estimated Completion Date. Used by Network Delivery. A restore date in most cases however can be related to specific work also (i.e. Survey ECD DD/MM/YY). |
EFRN |
Enter Fault Report Notes |
EF |
Exchange Failure |
ELF |
Early Life Failure (3 to 30 days) |
EMP |
Equivalence Management Platform |
EMR* |
Engineer Maintenance, check local cabling. Not reported by customer. |
EM |
Distance to Fault (Exch MDF) |
EN |
Equipment Number |
EOD |
Enter Order Details |
EOL |
Enter Order Lines |
EON |
Enter Order Notes |
EO |
Enter Order |
EP |
Distance to Fault (Exchange to PCP) |
ERT |
Estimated Response Time. The date Openreach communicates to the CP when we estimate an engineer will begin investigating a fault |
ESF |
Exchange Service Facility calling features and gain increases |
EST |
Estimated time to resolve or review times |
ES |
Legacy System X Exchange Fault |
EU |
End user |
EU |
Legacy UXD5 Exchange Fault |
EWI |
Executing With Works Instructions - The work has been printed off and given to someone to complete |
EXC |
Executing -The work is being done |
EXFO |
A device that is used to test Fibre Circuits (this may be seen in Engineers notes in the context of EXFO speed measurements are xxxx) |
EX |
Exchange Fault / Located in the Exchange |
EY |
Legacy AXE Exchange Fault |
Earth |
Low electricity - losing power - an earth fault is normally at the Local Network |
Exchange Group |
Unique identifier allocated to each exchange |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|